  • E+E Elektronik EE800 [EE800-M11] CO2 / Temperature Transmitter

E+E Elektronik EE800 [EE800-M11] CO2 / Temperature Transmitter

Not yet rated Write a review
E+E Elektronik

Available Options

Rp.16.333.000
Availability:
4 - 6 WEEKS
Product Code:
EE800-M11
Brand:
E+E Elektronik
Update Terakhir:
23 Sep 2023
  • Free delivery

  • Money back guarantee

Share

The EE800 is optimized for demand controlled ventilation and buildingautomation in residential and commercial applications.

Versatile
The EE800 combines CO2, temperature (T) and relative humidity (RH)measurement in one device with modern design. Additionally, itcalculates the dew point temperature (Td).

Outstanding Measurement Performance
The EE800 incorporates the E+E dual wavelength NDIR CO2 sensor,which compensates for ageing effects, is highly insensitive to pollutionand offers outstanding long term stability. A multiple point CO2 and Tfactory adjustment procedure leads to excellent CO2 measurementaccuracy over the entire T working range.

Analogue Outputs, Digital Interface,Display
EE800 features analogue outputs or RS485 interface. At the EE800 with RS485 additional physical quantities areavailable via Modbus RTU or BACnet MS/TP: absolute humidity, mixing ratio, enthalpy, frost point temperature and watervapor partial pressure. The optional display shows the measured values alternately.Easy Installation and MaintenanceThe EE800 enclosure is available in two sizes according to regional standards.The snap-on design facilitates the replacement of the active front part within seconds while the wiring remains intact.Furthermore, it makes possible to wire the device without exposing the electronics to construction site pollution.

Configurable and Adjustable
An optional USB configuration adapter and the free EE-PCS Product Configuration Software facilitate easy setup andadjustment of EE800.

  • CO2 range:0 to 2000 ppm
  • 0 to 5000 ppm
  • 10 to 90% RH range
  • -4 to 140°F (-20 to 60°C) temp range
  • ±(50ppm 2%/3%) CO2 accuracy
  • Humidity accuracy:±3 % RH (30 to 70% RH)
  • ±5 % (10 to 90% RH)
  • CO2 auto calibration
  • BACnet, Modbus or analogue outputs
  • Temperature compensation
  • Highly insensitive to pollution
  • Snap-on enclosure

  • CO2:
  • Measurement principle: Dual wavelength non-dispersive infrared technology (NDIR)
  • Measuring range: 0...2000 / 5000 ppm
  • Accuracy at 25 °C (77 °F): 0...2000 ppm: < ± (50 ppm +2 % of measuring value); 0...5000 ppm: < ± (50 ppm +3 % of measuring value)
  • Response time τ63, typ.: 110 s
  • Temperature dependence, typ.: ± (1 + CO2 concentration [ppm] / 1000) ppm/°C (-20...45 °C) (-4...113 °F)
  • Calibration interval1):  > 5 years
  • Temperature:
  • Accuracy2) at 20 °C (68 °F): ±0.3 °C (±0.54 °F) RS485 interface or voltage output;   ±0.7 °C (±1.26 °F) current output
  • Relative humidity: 
  • Working range:  10...90 %RHAccuracy at 20 °C (68 °F);  ±3 % RH (30...70 %RH) ±5 % (10...90 %RH)
  • Dew point temperature3): 
  • Working range: -30...55 °C (-22...131 °F) 
  • Accuracy:  < ±2 °C (3.6 °F) for |T| - |Td| < 25 °C (45 °F);   < ±3 °C (5.4 °F) for |T| - |Td| < 30 °C (54 °F)
  • 1) Under normal operating conditions.2) For supply voltage 24 V DC. Load resistor 250 Ω for version with current output3) Additional calculated physical quantities available only on the Modbus and BACnet interface: absolute humidity, mixing ratio, enthalpy,frost point temperature and water vapor partial pressure
  • Outputs:
  • Analogue:
  • 0...2000 / 5000 ppm: 0 - 10 V:  -1 mA < IL < 1 mA; 4 - 20:  mA RL < 500 Ohm
  • Digital interface: RS485 (EE800 = 1 unit load)
  • Protocol: Modbus RTU or BACnet MS/TP
  • General: 
  • Power supply: class III 4) 24 V AC ±20 %; 15 - 35 V DC
  • Current consumption, typ.:
  • Analogue:  14 mA + output current; Peak: 0.3 A for 0.3 s
  • Digital Bias: 11 mA at 15 - 35 V DC 30 mA at 24 V AC ±20 %; Peak: 150 mA at 15 - 35 V DC, 24 V AC ±20 %
  • Enclosure (polycarbonate): US Version: UL94V-0 approved / EU Version: UL94HB approved
  • Protection rating: IP30
  • Display5): LC display: alternating CO2 / T / RH or Td
  • Electrical connection: Screw terminals max. 1.5 mm2 (AWG16)
  • Electromagnetic compatibility: EN 61326-1 EN 61326-2-3; FCC Part 15 ICES-003 Class B
  • Test report: According to DIN EN 10204-2.2
  • Working / storage T range:  0...90 % RH (non condensing) / -20...60 °C (-4...140 °F)
  • 4) USA & Canada: class 2 supply required, max. supply voltage 30 V5) Analogue outputs: The display shows the physical quantities selected for the outputs.Digital interface: The display shows CO2 and T for Model M11 and CO2, T, and RH for Model M12
  • Enclosure:
  • EU: W x H x D = 85 x 100 x 26 mm (3.3 x 3.9 x 1");
  • US: W x H x D = 85 x 136 x 26 mm (3.3 x 5.4 x 1")
  • Colours:EU-Standard, US:Front cover: signal white RAL9003Back cover: light grey RAL7035

  • (1) EE800 Transmitter according to ordering guide
  • (1) Mounting materials
  • (1) Test report according to DIN EN10204 - 2.2
  • (1) Quick Guide - EE800 with digital interface (only for EE800 with RS485 interface) 

Download

Note: Prices are not binding at any time subject to change without prior notice


  EE800 MODEL 0 Item Selected
Image
Model
Product Name
Price
Available
Quantity
[M11] CO2 & temperature
M11
Rp.16.333.000
1 Availability
  EE800 CO2 RANGE 0 Item Selected
  EE800 OUTPUT 0 Item Selected
  EE800 REGONAL DESIGN 0 Item Selected
  EE800 DISPLAY 0 Item Selected
  EE800 TEMPERATURE UNIT 0 Item Selected
  EE800 LOW TEMPERATURE RANGE 0 Item Selected
  EE800 HIGH TEMPERATURE RANGE 0 Item Selected
  EE800 OUTPUT PARAMETER 3 0 Item Selected
  EE800 PROTOCOL 0 Item Selected
  EE800 BAUD RATE 0 Item Selected